PC-PIR15: No Counts

Last Updated: 2/3/2010 4:16:25 PM

Content
 
Troubleshoot
  1. Check the SS-TD10 Sensor
    • When an object moves into the detection area, does the red LED indicator flash?
      • No: Verify the 9V battery is functioning.
        • Low batteries can also cause extra counts, in addition to no counts.
        • If the battery is dead, the LED will not illuminate at all.
    • Does the red LED indicator flash when nothing is in the detection area?
      • Yes: Verify the 9V battery is functioning.
        • Low batteries can also cause extra counts, in addition to no counts.
        • If the battery is dead, the LED will not illuminate at all.
    • Is this a new installation?
      • Yes: There may be a positioning issue, or the sensor may be set to an incorrect detection pattern. (Refer to the SS-TD10 Manual.)
    • Is the sensor in range of the receiver?  (1000’ line of sight.)
      • No: Move the receiver to within 1000’ (line of sight) for a functioning transmitter range.
  2. Check the PC-Display (PC-PIR15-D)
    • Does the counter on the display increment when a connection is created between the IN and terminals (with the power supply connected to the display, use a piece of wire or paperclip to create the connection - several moments - and then breaking it)?
  3. Check the PCDL-1000 Count Recorder (PC-PIR15-R)
  4. Check the SS-RC10 Receiver
    • Does the chime ring, but the counter doesn’t increment?
      • Yes: The output mode may have changed.
        • To change the Output Mode, press Switch 1 two times within two seconds. Then press Switch 2 to cycle through the options.
          • No Output: ●○○○
          • Regular Mode with 1 second pulse on output: ●●○○
          • Regular Mode with 5 second pulse on output:  ●○●○
          • Regular Mode with 30 second pulse on output:  ●○○●
          • Regular Mode with 60 second pulse on output:  ●●●●
          • Utility Output Mode:  All red indicators will flash.
    • Could the settings have changed?
      • Yes: The simplest solution is to restore factory settings and re-detect the TD10 sensor(s).
        • Restore factory settings by holding switch 1 while applying power.
        • The RC10 will automatically restart in Learn Mode. (If the RC10 is not in Learn Mode, hold down switch one until the power indicator starts to flash.)
        • Wave your hand in front of the sensor to teach zone 1.
        • If there are addition sensors and zones, use switch 2 to go to the next zone. (Corresponding indicator will flash to indicate zone.  All three indicators indicates zone 4.) Wave hand in front of corresponding sensor.
        • Repeatedly press switch 2 to until all zone indicators are off to return to normal operation status.
  5. Check the wiring
    • Refer to the PC-PIR15-D (w/ PC-Display) diagram: Figure 1
    • Refer to the PC-PIR15-R (w/ PCDL-1000 Count Recorder) diagram: Figure 2
Figure 1
Figure 2
 